TD Lambda RWS-B Series
50-600W Single Output General Purpose Power SuppliesFeatures Low CostWide Range AC Input 85 - 265VAC (300VAC for 5s) UL508 Certi?cation on Select Models Enclosed Construction Compact Size 7 Year Warra
50-600W Single Output General Purpose Power SuppliesFeatures Low CostWide Range AC Input 85 - 265VAC (300VAC for 5s) UL508 Certi?cation on Select Models Enclosed Construction Compact Size 7 Year Warra
Low Cost
Wide Range AC Input 85 - 265VAC (300VAC for 5s)
UL508 Certi?cation on Select Models
Enclosed Construction
Compact Size
7 Year Warranty
Speci?cations | |||||||
Model RWS50B RWS100B RWS150B RWS300B RWS600B | |||||||
AC Input Voltage range (1) | VAC | 85 - 265VAC (47 - 63Hz), 300VAC for 5 seconds | |||||
DC Input Voltage range | VDC | 120 - 370VDC (330VDC for RWS600B)* | |||||
Inrush Current (100 / 200VAC) | A | 18 / 36 | 15 / 30 | 16 / 32 | 17 / 34 | 20 / 40 | |
Power Factor (100 / 200VAC) | - | Meets EN61000-3-2 (0.95 / 0.9) | |||||
Input Current (115/230VAC) (Typ) |
A |
1.0 / 0.65 | 1.2 / 0.6 (5V: 0.9/0.45) | 1.8 / 0.9 (5V: 1.3/0.7) | 3.6 / 1.9 (5V: 3.1/1.6) | 6.6 / 3.6 (5V: 6.2/3.2) | |
Temperature Coe?cient | - | <0.02%/°C | |||||
Regulation | - | See sheet 2 | |||||
Overcurrent Protection | - | >105%, Constant Current Style | |||||
Overvoltage Protection | V | 115-140%, Cycle AC line to reset | |||||
Hold Up Time (Typ at 100% load) | ms | 20ms (RWS50B: 15ms at 100VAC input) | |||||
Leakage Current (max) | uA | 750uA maximum, typically 175uA at 115VAC, 63Hz | |||||
Remote Sense | - | No | |||||
Operating Temperature | - | -20 to +70oC, see note (3) and instruction manual for low temperature derating | |||||
Storage Temperature | - | -30 to +75°C | |||||
Operating Humidity (non condensing) | %RH | 30 - 90%RH | |||||
Storage Humidity (non condensing) | %RH | 10 - 90%RH | |||||
Cooling | - | Convection | Internal Fan | ||||
Withstand Voltage | - | Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. | |||||
Isolation Resistance | - | >100M at 25°C & 70%RH, Output to Ground 500VDC | |||||
Vibration (non operating) | - | 10 - 55Hz: 19.6m/s2 (sweep 1 min) X, Y, Z for 1 hour | |||||
Shock | - | < 196.1 m/s2 | |||||
Safety Agency Approvals (2) | - | UL / CSA(cUL) / IEC 60950-1 (2nd Ed), UL:508, CSA C22.2 No.107.1-01, CE Mark (Additionally evaluated to EN 60950-1) | |||||
Conducted & Radiated EMI | - | EN55011 / EN55022-B, FCC Class B, VCCI-B | |||||
Immunity | - | IEC61000-4-2, -3, -4, -5, -6, -8, -11, IEC61000-6-2 | |||||
Weight (Typ) | g | 230 | 400 | 480 | 900 | 1600 | |
Size (WxHxD) | mm | 82 x 34 x 81.5 | 94 x 39 x 108 | 94 x 41 x 128 | 102 x 41 x 170 | 120 x 61 x 190 | |
In | 3.23 x 1.34 x 3.2 | 3.7 x 1.54 x 4.25 | 3.7 x 1.61 x 5.04 | 4.02 x 1.61 x 6.7 | 4.72 x 2.4 x 7.48 | ||
MTBF - Telcordia SR-332 issue 3** | Hours | 4,170,949 | 1,978,533 | 2,235,743 | 2,027,824 | 2,157,340 | |
Warranty | Yrs | Seven Years |